Technical Specification Of Electrostar Make "ESTAR" Brand Surge Suppressor
Scope : The use of surge suppressor is to protect electronic equipment from high transient voltage and to limit the duration and frequency of the amplitude of output current
|
A.C.input
|
230V. A.C + 10% 50 Hz 1 ph.
|
|
A.C. Cord length
|
6 feet, 3 core, 15 amps, NETCO make (One ANCHOR make socket to be provided at one end of the input cord).
|
|
Miniature. Circuit breaker (Resettable)
|
One 16 amp Miniature circuit breaker to be provided on input side.
|
|
Load handling capacity
|
2200 watt maximum or 10 amp per socket.
|
|
Output socket
|
4 No. 15 amps socket (ANCHOR MAKE)
|
|
Impulse discharge Current (wave 8/20 µs)
|
13000 amps.
|
|
Transient energy (wave 10/1000µs)
|
600 joules.
|
|
Transient suppression
|
Handles up to 13 KA spikes protection in all 3 Modes-Live to Neutral, Live to Ground and Neutral to Ground.
|
|
Surge impulse test between live & neutral, earth grounded amplitude 2KV/ 1.2/50µs super imposed on 230 Volt AC Mains.
|
Suppressed output Peak voltage less than 200V volts over 230 V.
|
|
Surge impulse test between live & neutral (non-superimposed)
- Energy of pulse: 2.5 Joules.
- Amplitude: 5 KV.
- Rise time: 1.2/50µs.
|
Suppressed output peak voltage not exceeding 800 volts.
|
|
High Frequency noise suppression
|
Greater than 10 db @ 50 Khz Greater than 30 db @ 150 KHz Greater than 35db @ 1 MHz Greater than 20 db @ 22 MHz Greater than 20 db @ 25 MHZ Greater than 15 db @ 50 MHz Greater than 35 db @ 100 MHz Greater than 25 db @ 200 MHz Greater than 25 db @ 300 MHZ Greater than 15 db @ 500 MHz Greater than 15 db @ 700 MHz Greater than 15 db @ 1000 MHZ |
|
Operating temperature
|
0 oC TO + 45 oC.
|
|
Dimension in inches (approx)
|
3.5 x 7 x 2.5.
|
|